All prices shown on Penlyon.co.uk are Suggested Selling Prices so may seem high. If you're interested in our product range please contact us for details of our trade prices.
AC mains 50/60Hz, or 24V DC (M4 screw terminal) Rated Power: 30W
AC operation: 80W (rated output),
24V DC operation: 7.0A (rated output).
2.8A (EN60065)
50 – 20,000Hz (±3dB)
Under 2% at 1kHz, rated power
MIC 1: –60dB*1, 600Ů, electronically-balanced, combined type of XLR-3-31 equivalent
and phone jack, DIN socket (5 pins)
MIC 2, 3: –60dB*1, 600Ů, electronically-balanced, combined type of XLR-3-31 equivalent and phone jack
AUX 1 (MOH): –20dB*1, 10kŮ, unbalanced, RCA pin jack
AUX 2: –20dB*1, 10kŮ, unbalanced, RCA pin jack
AUX 3: –20dB*1, 10kŮ, unbalanced, combined type of XLR-3-31 and phone jack
TEL*2: –20dB*1, 10kŮ, electronically-balanced, M3 screw terminal
EMERGENCY: 0dB*1, 600Ů, unbalanced, M3 screw terminal
REC: 0dB*1, 600Ů, unbalanced,
RCA pin jack
LINE 1, 2*3: 0dB*1, 600Ů,
unbalanced, RCA pin jack
MOH: 0dB*1, 600Ů,
transformer balanced,
M3 screw terminal
SPEAKER SELECTOR: 2 zone,
high impedance (100V line/83Ů),
individual selector switch,
M4 screw terminal
DIRECT SPEAKER OUT:
High impedance (100V line/83Ů),
M4 screw terminal
Low impedance (4 – 16Ů),
M4 screw terminal
(Both Low and High impedance terminals cannot be used at the same time.)
ON or OFF for each MIC 1 – 3 with switch setting
Over 100dB (Master volume: min)
Over 76dB (Master volume: max)
Over 60dB (MIC 1 – 3))
Over 76dB (AUX 1 – 3)
Over 90dB (TEL)
Over 96dB (EMERGENCY)
Bass: ±10dB at 100Hz, Treble: ±10dB at 10kHz
TEL: No-voltage make contact input, open voltage: 24V DC,
short-circuit: under 5mA, M3 screw terminal
EMERGENCY*4: No-voltage make contact input, open voltage: 24V DC,
short-circuit: under 10mA, M3 screw terminal
Power remote: Open collector output, withstand voltage: 35V DC,
control current: under 50mA, M3 screw terminal
1-tone, 2-tone, or ascending 4-tone chime, or None selectable with switch setting
activated at MIC 1's DIN or CONTROL TEL terminal
5 point LED output level meter, Power indicator LED, Zone indicator LED,
Emergency LED, TEL LED
EMERGENCY: Overrides other inputs
TEL: Overrides other inputs except “EMERGENCY”, ON/OFF selectable with switch setting
MIC 1: Overrides other inputs except “EMERGENCY & TEL”, ON/OFF selectable with switch setting
–10°C to +40°C
Panel: ABS resin, black, hair line
Case: Steel plate, black
420 (W) x 107.7 (H) x 367 (D)mm
12.6kg
340.95 (SSP)